<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Medical Journal of the Islamic Republic Of Iran</title>
<title_fa>مجله پزشکی جمهوری اسلامی ایران</title_fa>
<short_title>Med J Islam Repub Iran</short_title>
<subject>Medical Sciences</subject>
<web_url>http://mjiri.iums.ac.ir</web_url>
<journal_hbi_system_id>2</journal_hbi_system_id>
<journal_hbi_system_user>journal2</journal_hbi_system_user>
<journal_id_issn>1016-1430</journal_id_issn>
<journal_id_issn_online>2251-6840</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.18869/mjiri</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1374</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>1995</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>DEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE</title>
	<subject_fa>Pharmacology</subject_fa>
	<subject>Pharmacology</subject>
	<content_type_fa>Original Research: Basic Science in Medicine</content_type_fa>
	<content_type>Original Research: Basic Science in Medicine</content_type>
	<abstract_fa></abstract_fa>
	<abstract>Aluminium determination was carried out in serum and dialysis fluid by a
simple and reliable method of nameless atomic absorption with graphite furnace . .
No preparatory procedures are required for water and dialysis fluid. In this method
serum was mixed with 0.2% HNO, to allow complete combustion of the samples
in order to improve analytical precision. The method has a sensitivity of 15 pg and
detection limit of 2.1 µg AI/L.
The aluminium contents of the main water supply, be-distilled water and
dialysis fluid were 52, I, and 44 µg/L respectively. The mean value for normal
serum aluminium in Isfahan was 3.6 µg/L. Serum aluminium concentration in
chronic renal failure was measured in pre- and post-dialysis samples. The mean
values for the serum aluminium levels pre- and post-dialysis were 30.5 and 71.08
µg/L with a range of 9-60 and 21-123 µg/L, respectively. Pre- and post-dialysis
serum aluminium values in female patients were within the range of 1-42 and 12-
66 µg/L with mean values of 18.25 and 40.5 µg/L, respectively. Instrumental
settings and sample handling are discussed.
</abstract>
	<keyword_fa></keyword_fa>
	<keyword></keyword>
	<start_page>233</start_page>
	<end_page>237</end_page>
	<web_url>http://mjiri.iums.ac.ir/browse.php?a_code=A-10-298-528&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>AA</first_name>
	<middle_name></middle_name>
	<last_name>MOSHTAGHIE</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>20031947532846005880</code>
	<orcid>20031947532846005880</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>From the Department of Biochemistry, School of Pharmacy Isfahan University of Medical Sciences, Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>SANDUGHCHIN</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>20031947532846005881</code>
	<orcid>20031947532846005881</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>From the Department of Biochemistry, School of Pharmacy Isfahan University of Medical Sciences, Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A</first_name>
	<middle_name></middle_name>
	<last_name>BADIL</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>20031947532846005882</code>
	<orcid>20031947532846005882</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>From the Department of Biochemistry, School of Pharmacy Isfahan University of Medical Sciences, Isfahan</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>AZANI</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>20031947532846005883</code>
	<orcid>20031947532846005883</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>the Dialysis Center, Shariati Hospital, Isfahan, I.R. Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
