Volume 14, Issue 3 (11-2000)                   Med J Islam Repub Iran 2000 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

POURSADEGH M, HASHEMI G, JALALI M. EVALUATION OF ANATOMICAL VARIATIONS OF VESTIBULAR AQUEDUCT DIMENSIONS IN TEMPOR AL BONE CT SCAN. Med J Islam Repub Iran 2000; 14 (3) :199-202
URL: http://mjiri.iums.ac.ir/article-1-852-en.html
From the Departments of Otolaryngology and Radiology, Emam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, IR. Iran.
Abstract:   (3950 Views)
Various dimensions of the human vestibular aqueduct were evaluated in two groups, patient and control, and these measurements were compared. Both groups were examined clinically, followed by audiometric evaluation and temporal bone high resolution CT scan. It was found that in approximately one third of the patient group (with idiopathic SNHL), the vestibular aqueduct was 1.5 mm or larger. Also, the midpoint diameter of the distal limb was larger than in the control group (p<0.01). But there was no relation between the various dimensions of the vestibular aqueduct and mastoid pneumatization.
Full-Text [PDF 570 kb]   (1565 Downloads)    
Type of Study: Original Research | Subject: Radiology

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.