Volume 29, Issue 1 (1-2015)                   Med J Islam Repub Iran 2015 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Baradaran Motie P, Zare-Mirzaie A, Shayanfar N, Kadivar M. Does routine repeat testing of critical laboratory values improve their accuracy?. Med J Islam Repub Iran 2015; 29 (1) :139-146
URL: http://mjiri.iums.ac.ir/article-1-2692-en.html
Iran University of Medical Sciences, Pathology Ward, Rasoul-e-Akram Hospital, Tehran, Iran. , zaremir@gmail.com
Abstract:   (4295 Views)

  Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not.

  Methods : We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin. The absolute difference and the percentage of change between the two tests for each critical value were calculated and then compared with the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error.

  Results : Repeat testing yielded results that were within the allowable error on 2213 of 2233 specimens (99.1%). There was only one outlier (0.2%) in the white blood cell test category, 9 (2.9%) in the platelet test category, 5 (4%) in the partial thromboplastin time test category, 5 (4.8%) in the international normalized ratio test category and none in other test categories.

  Conclusion : Routine, repeat testing of critical hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin results does not have any benefits to increase their accuracy.

Full-Text [PDF 998 kb]   (2113 Downloads)    
Type of Study: Original Research | Subject: Pathology

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.