Volume 33, Issue 1 (2-2019)                   Med J Islam Repub Iran 2019 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farahmand B, Ebrahimi Takamjani E, Yazdi H R, Saeedi H, Kamali M, Bagherzadeh Cham M. A systematic review on the validity and reliability of tape measurement method in leg length discrepancy. Med J Islam Repub Iran 2019; 33 (1) :281-287
URL: http://mjiri.iums.ac.ir/article-1-5176-en.html
Neuromusculoskeletal Research Center, Department of Physical Medicine and Rehabilitation, Iran University of Medical sciences, Tehran, Iran , masumehbagherzadeh@gmail.com
Abstract:   (3084 Views)
Background: Leg length discrepancy measurement is an essential part of musculoskeletal clinical assessment, and tape measurement is a common clinical method. This study aimed to systematically review the results of the findings of studies on validity and reliability of the tape measurement method and the quality of reporting the literature on this topic.
   Methods: A search was performed in PubMed, EBSCO, Science Direct, Web of Knowledge, Scopus, Embase, and Google Scholar using selected keywords from inception to December 2017.This systematic review was based on the PRISMA guideline. After a systematic selection process, the quality of the included studies was assessed independently by 2 reviewers using the Brink and Louw Scale for quality assessment.
   Results: A total of 11 studies were finally considered for this systematic review. Two studies were about the validity of (a measurement tool) studies and 4 were reliability analysis only. Validity and reliability analyses were simultaneously applied to 5 studies. Also, 9 out of 11 studies were deemed to be of high quality based on Brink and Louw Scale. Studies showed high (ICC=0.7) to very high (ICC=0.9) levels of interrater and intrarater reliability. The validity of the methods ranged from low to very high depending on subjects.
   Conclusion: Tape measurement method has acceptable reliability and validity in healthy people, but it does not have acceptable validity in measuring obese people and patients with musculoskeletal disorders. Thus, using a suitable method for LLD leg length discrepancy measurement seems to be necessary for obese and individuals with leg length discrepancy.
 
Full-Text [PDF 431 kb]   (761 Downloads)    