Fadavi P, Mehrabian A, Salmanian S, Mahdavi S R, Yousefi Diba A A, Javadinia S A. The Relationship between Lung and Heart Two-Dimensional Parameters and Three-Dimensional Dose-Volume Data in Adjuvant Radiotherapy for Breast Cancer. Med J Islam Repub Iran 2022; 36 (1) :124-131
URL:
http://mjiri.iums.ac.ir/article-1-7621-en.html
Department of Radiation Oncology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran , mehrabian.a@iums.ac.ir
Abstract: (1259 Views)
Background: Two-dimensional (2D) radiographic parameters have been used to estimate the amount of heart and lung irradiated for minimizing heart and lung complications in breast cancer patients. The aim of this study was to investigate the correlation between traditionally used 2D radiographic and dose-volume parameters during adjuvant radiotherapy of breast cancer.
Methods: In this cross-sectional study, we analyzed 121 female patients treated with breast-conserving surgery (BCS) or modified radical mastectomy (MRM) and 3D conformal radiotherapy (3DCRT) using two-field radiotherapy (2FRT) or three-field radiotherapy (3FRT) technique. All patients underwent computed tomography (CT)-planning. Two-D parameters, including central lung distance (CLD), maximum lung depth (MLD), maximum heart length (MHL), maximum heart distance (MHD), and chest wall separation (CWS), were measured using digitally reconstructed radiographs (DRR) and CT images. DVHs for lung, heart, and target were created. The Pearson correlation test was used to evaluate the correlation between 2D radiographic and dose-volume parameters.
Results: There was a correlation between CLD and ipsilateral lung V5-20Gy and Dmean and between MLD and ipsilateral lung V5-20Gy. In 2FRT, only moderate correlation between CLD and ipsilateral lung V20Gy (r = 0.453, P = 0.003) and between MLD and ipsilateral lung V20Gy (r = 0.593, P <0.001) were observed. Poor correlation of MHL and heart V25Gy (r = 0.409, P = 0.007) was seen only in 3FRT. There was a correlation between MHD and heart dose-volume data, with a strong correlation between MHD and heart V5-25Gy and Dmean (r = 0.875-0.934, P<0.001) in the 2FRT group. No correlation between CWS and breast Dmax was found.
Conclusion: There was a correlation between 2D parameters (i.e., CLD, MLD, and MHD) and the heart and lung dose-volume parameters during adjuvant breast radiotherapy. Although CLD was correlated to ipsilateral lung V5-20Gy and Dmean, the correlation between CLD and ipsilateral lung V20Gy was greater than other dose-volume parameters. MHD provided a close estimation of heart dose-volume parameters.
Type of Study:
Original Research |
Subject:
Oncology